General Information |
Manufacturer |
Hewlett Packard |
Manufacturer Part Number |
J4817A#ABA |
Product Line |
ProCurve |
Product Name |
ProCurve 2312 Ethernet Switch |
Marketing Information |
The HP ProCurve Switch 2312 is low cost, unmanaged 12-port switch with 10/100 auto-sensing per port and 2 open transceiver slots for Gigabit or 100Base-FX uplinks. The HP ProCurve Switch 2312 offer HP Auto-MDIX on all 10/100 and 100/1000 uplink ports. |
Manufacturer Website Address |
www.hp.com |
Networking |
Device Type |
Ethernet Switch |
Ports |
12 x 10/100Base-TX |
Ports Details |
12 x RJ-45 10/100Base-TX Port(s) Auto MDI/MDI-X
1 x DB-9 Console Port(s) Management |
Expansion Slots |
2 x Expansion Slot(s) |
Slots Details |
2 x Expansion Slot(s) |
Flow Control |
IEEE 802.3x (Full-duplex) |
Media & Performance |
Connectivity Media |
Twisted Pair 10/100Base-TX |
Data Transfer Rate |
100Mbps Fast Ethernet
10Mbps Ethernet |
Performance |
6.6Mpps Throughput for 64-byte Packet(s)
9.6Gbps Switching Fabric |
Protocols & Management |
Status LEDs |
Comprehensive LED display with per-port indicators:
Provides an at-a-glance view of status, activity, speed, and full-duplex operation
|
Processor & Storage |
Processor |
1 x ARM7TDMI 62.5MHz |
Memory |
6MB Buffer Memory Shared
26MB Main Memory
2MB Flash Memory |
Miscellaneous |
Additional Information |
Address table size: 4,096 entries
HP Auto-MDIX:
Automatically adjusts for straight-through or crossover cables on all 10/100 and 100/1000 ports
Media-flexible uplink ports:
Provides Gigabit or 100-FX ports for uplinks or server connections
10/100 autosensing per port:
Automatically detects and sets the speed for any 10Base-T or 100Base-TX device
Flow Control:
Ensures reliable communication during full-duplex operation
Unmanaged:
Provides plug-and-play simplicity
|
Bill of Materials |
Mounts in a standard 19-in rack (hardware included)
|
Certifications & Standards |
Safety:
EN 60950/IEC 950
UL 1950: CSA 950
Complies with NOM-019-SCFI-1994
Emissions:
FCC Class A
EN 55022/CISPR-22 Class A
VCCI Class A
Immunity:
EN 55024/CISPR 24
ESD: IEC 61000-4-2; 4kV CD, 8kV AD
radiated: IEC 61000-4-3; 3V/m
EFT/Burst: IEC 61000-4-4; 1.0kV (power line), 0.5kV (signal line)
Surge: IEC 61000-4-5; 1kV/2kV AC, 1kV signal, 0.5kV signal line
Conducted: IEC 61000-4-6; 3V
Power freq. magnetic field: IEC: 61000-4-8; 1A/m, 50 or 60 Hz
Voltage dips or interruptions: IEC 61000-4-11; >95% reduction: 0.5 periods, 30% reduction: 25 periods
EN 61000-3-2/IEC 61000-3-2; harmonics
EN 61000-3-3/IEC 61000-3-3; flicker
|
Power Description |
Input Voltage |
100 to 127V AC
200 to 240V AC |
Input Current |
Up to 2.4A @ 100 to 127V AC
Up to 1.2A @ 200 to 240V AC |
Frequency |
50 to 60Hz |
Power Consumption |
Up to 36W |
Power Supply |
Integrated |
Environmental Conditions |
Temperature |
0 to 55°C (32 to 131°F) Operating
-40 to 70°C (-40 to 158°F) Storage |
Humidity |
90% Non-condensing Relative Humidity Storage
15 to 95% Non-condensing Relative Humidity Operating |
Thermal Dissipation |
123 BTU/h |
Physical Characteristics |
Form Factor |
19" Rack-mountable |
Dimensions |
1.8" Height x 17.4" Width x 8" Depth |
Shipping Dimensions |
6.00" Height x 11.5" Width x 22.75" Depth |
Weight |
6.0 lb |
Shipping Weight |
8.84 lb |
Warranty & Support |
Standard Warranty |
Lifetime Limited |
Parts Warranty & Labor |
Lifetime |
Additional Warranty Information |
Bring-in
With next-business-day advance replacement
|